Chem-skid
Chemical Resistant Epoxy Floor Surfacer (S2617)
Chem-skid is a flooring system designed to be applied over concrete
or steel in severe industrial environments. This product cures to form a
hard, tough and chemically resistant coating.
Chem-skid can be used with a grit additive to provide a textured,
non-slip flooring which can be applied up to 1/8 thickness. High film build
characteristics will provide a thick film with excellent abrasion resistance
and can also be used to fill pitted concrete holes and voids.
Chem-skid is 100% volume solids which is compliant with all VOC
(volatile organic compounds) regulations and since it contains no solvents
it has no flash point.
Chemical Resistance (splash & spillage):
10% Sulfuric Acid no effect*
10% Phosphoric Acid no effect*
10% Hydrochloric Acid no effect*
10% Nitric Acid no effect*
10% Acetic Acid no effect*
10% Sodium Hydroxide no effect*
Water, oil, grease no effect*
*Some discoloration may occur, but coating will not soften or be removed.
Recommended Uses:
Battery Plants.... Pulp & Paper Mills.... Acid Plants.... Mining/Refining
Plants.... Offshore Plants.... Chemical Spill Areas.... Chemical Processing
Plants.....
Any other areas where chemicals attack concrete or where ease of cleaning
or non-skid characteristics are needed.
Kit Description:
2 GALLON KIT: Base Component(S2617) 1 gallon in a gallon container. Activator
Component(S2698) 1 gallon in a gallon container. 10 GALLON KIT: Base Component(S2617)
5 gallons in a 5 gallon container. Activator Component (S2698) 5 gallons
in a 5 gallon container.
Technical Data
TYPE: Amine Cured Epoxy
COMPONENTS: 2
COLORS: Gray (S2617) / Special colors available with minimum 100
gallon order.
GLOSS: high
FLASH POINT: 155°F (68°C) activated
VOC: maximum 2.8 Ibs/gal (340 g/1) after thinning
SOLIDS BY VOLUME: 100%
RECOMMENDED FILM THICKNESS: For smooth surfaces, 25 mils. As a
non-skid overlay, 1/8 inch
SPREADING RATE: Theoretical is 64 square feet per gallon for smooth
surfaces. As a non-skid overlay, 13 square feet per gallon
SURFACE PREPARATION: CONCRETE--Surface shall be dry and free of
dirt, grease, oil, curing compounds, release compounds or other contaminants.
Chemical and for steam cleaning may be necessary to fully remove such contaminants.
Following decontamination, the concrete surface should be blast cleaned
to remove laitance and to provide an open surface to which the coating can
adhere. The preferred method of blast cleaning is the use of self-contained
centrifugal equipment such as a Blastrac. In some cases, acid etching with
10% Muriatic Acid may be used in lieu of blasting, but acid etched concrete
must be properly neutralized, rinsed, dried, wire brushed and vacuumed to
remove dust. Concrete must cure a minimum of 28 days prior to coating. STEEL--Surface
must be free of dirt. grease, oil, moisture and other contaminants. For
severe exposures, blast clean in accordance with SSPC-SP 10, Near White
Blast Cleaning, to an average surface profile of 2.5-3.0 mils. For non-severe
service, blast clean in accordance with SSPC-SP 6, Commercial Blast Cleaning,
to an average profile of 2.5-3.0 mils.
MIXING: See application instructions below.
POT LIFE: Twenty minutes at 77°F (25°C). Chem-skid must
be stored inside before application. If stored outside in the sun, material
will become warm and shorten the pot life.
SHELF LIFE: 1 year @ 60-90°F (15-32°C)
APPLICATION: SMOOTH GLOSS FLOOR OVER CONCRETE: Using mechanical
agitation, mix 1 gallon of Base Component (S2617) with 1 gallon of Activator
Component (S2698) and add 1 quart of Thinner S6684 (xylene). Immediately
pour this mixture onto the floor. Once the mixture is on floor, the working
life is longer. With a roller, brush, squeegee or broom, spread a thin coat
over the area at about 230 square feet per gallon. Allow this seal coat
to dry. Mix another gallon of base and activator, DO NOT ADD THINNER, and
apply at 90 square feet per gallon. On rough Floors spreading rate will
be less than 90 feet. NON-SKID OVERLAY: Using mechanical agitation, mix
1 gallon of Base Component (S2617) with 1 gallon of Activator Component
(S2698). DO NOT ADD THINNER. Immediately pour this mixture onto the floor
and spread with a roller, brush, squeegee or broom at about 230 square feet
per gallon. This serves as a primer/sealer. It is not necessary to wait
for this coat to dry. Immediately mix another gallon of base and activator
and pour into Grit Component (approximately 35 lbs. of grit in a 5 gallon
container) and mix thoroughly. DO NOT ADD THINNER. Immediately pour onto
floor and use a trowel to spread at 13 square feet per gallon. This will
result in an overlay l/8 inch thick.
DRY TIME @ 77°F (25°C):
Light traffic.............. 5 hours
Normal service...... 16 hours
PRIMER: none
THINNING: See application instructions above.
CLEAN UP: Thinner S6684 (xylene)
FOR PROFESSIONAL USE ONLY
Pratt & Lambert, Inc.
"Technical services, advice, and recommendations are
rendered free. They are based on technical data which we believe to be
reliable and are intended for use by persons having skill and know how,
at their own discretion and risk We assume no responsibility for results
obtained or damages incurred from their use by the Buyer in whole or in
part "
Pratt & Lambert Industrial Product Index
SPECTRA
PAINT CENTERS HOME
Electronic Mail:
mail@spectrapaint.com
Copyright © 1999 Spectra Paint Centers
All rights reserved. |